Kramer-electronics VP-790 Manual de usuario Pagina 99

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 98
VP-790 Protocol API Functions 95
2.88.2 389BbyOsdPipYGet
API index: 3215
Retrieves the PiP Vertical Position from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0 ... 100
PIP Vertical position in % of the main
image, i.e. 0% PiP top edge aligns
with main top edge and 100% PiP
bottom edge aligns with bottom edge.
2.88.3 390BbyOsdPipYSave
API index: 3216
Saves the PiP Position setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.89 97BPTZ Aspect Ratio Lock
2.89.1 391BbyOsdPtzAspectSet
API index: 3237
Gives access to the vertical zoom slider for asymmetric zoom/shrink when Aspect
Lock is Off.
Input Parameters
Name Type Range Description
Value UWORD32 0: On
1: Off
Switch Aspect Lock on or off.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise