Vista de pagina 92
VP-790 Protocol API Functions 89
2.82 90BPIP H-Pos
2.82.1 371BbyOsdPipXSet
API index: 3211
Sets the PiP Horizontal Position.
Input Parameters
Name Type Range Description
Value UWORD32 0 ... 100
PiP Horizontal position in % of the
main image, i.e. 0% PiP left edge
aligns with main left edge and 100%
PiP right edge aligns with main right
edge.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.82.2 372BbyOsdPipXGet
API index: 3212
Retrieves the PiP Horizontal Position from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0 ... 100
PIP Horizontal position in % of the
main image, i.e. 0% PiP left edge
aligns with main left edge and 100%
PiP right edge aligns with main right
edge.
2.82.3 373BbyOsdPipXSave
API index: 3213
Saves the PiP Horizontal Position setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise