VP-790 Protocol API Functions 91
2.84 92BPIP Mode
2.84.1 377BbyOsdPipOnOffSet
API index: 315
Sets the PiP mode.
Input Parameters
Name Type Range Description
Value UWORD32 0: Off
1: PIP
2: PAP
3: POP
PIP mode
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.84.2 378BbyOsdPipOnOffGet
API index: 317
Retrieves the PiP mode setting from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: Off
1: PIP
2: PAP
3: POP
PIP mode
2.84.3 379BbyOsdPipOnOffSave
API index: 316
Saves the PiP mode setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise