80 VP-790 Protocol - API Functions
2.72.2 byOsdLanguageGet
API index: 447
Retrieves the OSD language setting from either cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0: English AE
1: English BE
2: German
Menu position
2.72.3 byOsdLanguageSave
API index: 446
Saves the OSD language setting from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.73 OSD Messaging
2.73.1 byOsdOsdMessagesSet
API index: 3273
Switches OSD Messaging On/Off.
Input Parameters
Name Type Range Description
Value UWORD32 0: Off
1: On
Switch OSD Messaging On/Off
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.73.2 byOsdOsdMessagesGet
API index: 3274
Retrieves the set-up of OSD messaging.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values