20 VP-790 Protocol - API Functions
2.9 Announce Server Port
2.9.1 byOsdSetAnnounceServerPort
API index: 4207
Set the Announce Message server port.
Input Parameters
Name Type Range Description
Value UWORD16 0x0000-0xFFFF (or
decimal 0 ... 65535)
Port
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.9.2 byOSDGetAnnounceServerPort
API index: 4206
Retrieve the Announce Message server port.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD16 0x0000-0xFFFF (or
decimal 0 ... 65535)
Port
2.9.3 byOsdSaveAnnounceServerPort
API index: 4208
Saves the Announce Message server port number from cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise