Kramer-electronics VP-790 Manual de usuario Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
104 VP-790 Protocol - API Functions
2.99.2 byOsdR/G/BGainGet
API indices: 2801/2804/2807
Retrieves the gain value from either the cache or the SPD.
Input Parameters
Name Type Range Description
Option BYTE 0: From cache
1: From SPD
Retrieval method
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Value UWORD32 0x00000000: 11/√2
0x7FFFFFFF: 1
0xFFFFFFFF: 1+1/√2
Contrast (signal gain)
2.99.3 byOsdR/G/BGainSave
API indices: 2802/2805/2808
Saves the gain level from the cache into the SPD.
Input Parameters
None
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
2.100 Rotation
2.100.1 byOsdRotationAngleSet
API index: 843
Sets the Rotation Angle.
Input Parameters
Name Type Range Description
Value SWORD32 -180 ..+180 Sets the Rotation Angle.
Return Values
Name Type Range Description
Status BYTE 0x00-0xFF 0 if successful, error code otherwise
Vista de pagina 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 125 126

Comentarios a estos manuales

Sin comentarios