Kramer-electronics VP-773AMP Manual de usuario Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
VP-773AMP - Port Tunneling
53
53
9 Port Tunneling
The port tunneling feature lets you send and receive simple RS-232 signals
between a controller and a serial device via the VP-773AMP which is connected to
the Ethernet and outputs via TP cable.
The example, illustrated in Figure 33, shows a Kramer room controller that is
connected to the VP-773AMP via the Ethernet. The HDBT OUT connector on the
VP-773AMP is connected via TP to an HDBT receiver. This HDBT receiver connects
to a display via HDMI and RS-232.
Figure 33: Port Tunneling
The room controller sends RS-232 signals over the Ethernet via a dedicated
Tunneling port to the VP-773AMP. The VP-773AMP sends these signals via TP to a
display that is connected to the receiver. This way, control data can flow between the
room controller and the display device, tunneling through the VP-773AMP.