Vista de pagina 46
Kramer Protocol 3000
43
NET-MAC?
Cmd Short Description Command Type Permission
NTMC? Read MAC address Ethernet End User
Usage:
Syntax Response
NET-MAC?
NET-MAC MAC_ADDRESS
NET-MASK
Cmd Short Description Command Type Permission
NTMSK Set subnet mask Ethernet Administrator
Usage:
Syntax Response
NET-MASK SUBNET_MASK
Ex: 255.255.000.000
NET-MASK SUBNET_MASK RESULT
NET-MASK?
Cmd Short Description Command Type Permission
NTMSK? Get subnet mask Ethernet End User
Usage:
Syntax Response
NET-MASK?
NET-MASK SUBNET_MASK
10.7 Instruction Codes
ALARM
Cmd Short Description Command Type Permission
Device notification PL-50 No security
Usage:
Syntax Response
ALARM 1/0
1/0= On OR Off
ALARM-DURATION
Cmd Short Description Command Type Permission
Set alarm duration PL-50 Administrator
Usage:
Syntax Response
ALARM-DURATION SECONDS
SECONDS = 0255
ALARM-DURATION SECONDS RESULT
ALARM-DURATION?
Cmd Short Description Command Type Permission
Query alarm duration PL-50 User
Usage:
Syntax Response
ALARM-DURATION?
ALARM-DURATION SECONDS