Technical Specifications
35
8.2 Changing the Device Parameters
To change the device parameters do the following:
1. Connect a PC to the PL-50 (see section
8.1.2).
2. Open K-UPLOAD (see
Figure 30).
3. Click the Connect button to open the Connect window (see
Figure 31).
4. Choose the appropriate type of connection: Ethernet, Serial or USB, and click
Connect.
The Connect window disappears and the Device Properties become visible.
5. Change the parameters as required and then click Save.
9 Technical Specifications
Table 10 includes the technical specifications:
Table 10: Technical Specifications
1
INPUT POWER SOURCE:
of the PL-50
For Europe: 230V AC, 50/60Hz, 10VA, internal
For the USA 130V AC, 130V AC, 50/60Hz, 10VA, internal
OUTPUTS: For Europe: 5 x 220-240V AC outputs, total load of 10A Max.
For the USA: 5 x 100-120V AC outputs, total load of 10A Max.
DIMENSIONS: 19-inch (W), 7-inch (D) 1U (H) rack-mountable
WEIGHT: 2.7kg (6lbs) approx.
ACCESSORIES: Power cord, Windows®-based Kramer control software,
Infrared remote control transmitter
1 Specifications are subject to change without notice