Using the SG-6005xl Genlock Multistandard SPG/Audio Generator
KRAMER: SIMPLE CREATIVE TECHNOLOGY
10
# Menu Item Submenu Default Value
FACTORY RESET Press ENTER to reset the
GENLOCK parameters
GENLOCK MODE HV only, HV and SC HV only
GENLOCK TIMING HORIZONTAL from -31968ns to
+31968ns (in 37ns steps)
1
0
GENLOCK TIMING VERTICAL from -625 line to +625 line 0
GENLOCK EXTRA V SHIFT -1 frame, 0 frame, +1
frame
0 frame
GENLOCK SC PHASE SHIFT
from -185° to +185°
0
NON-GENLOCK or HVmode
SCHphase
from -64° to +63°
0
8 TEST 1 PROGRAMMING TEST 2 PROGRAMMING
9 ADDRESS OF machine First, Second First
7.2 Locking the Front Panel
To prevent changing the settings accidentally or tampering with the unit via the
front panel buttons, lock your SG-6005xl. Unlocking releases the protection
mechanism.
To lock the SG-6005xl:
• Press the LOCK button for more than three seconds, until the LOCK button
lights
The front panel is locked. Pressing a button will have no effect other than
causing the LOCK button to flash
1
To unlock the SG-6005xl:
• Press the lit LOCK button for more than three seconds, until the LOCK
button no longer lights
The front panel unlocks
7.3 Remotely Operating via RS-232
You can remotely operate the SG-6005xl via RS-232 using a device such as a PC.
To connect a PC to the SG-6005xl unit using the Null-modem adapter
provided with the machine (recommended):
• Connect the RS-232 9-pin D-sub rear panel port on the SG-6005xl unit to
the Null-modem adapter and connect the Null-modem adapter with a 9-wire
flat cable to the RS-232 9-pin D-sub port on your PC
To connect a PC to the SG-6005xl unit without using a Null-modem adapter:
• Connect the RS-232 9-pin D-sub port on your PC to the RS-232 9-pin D-sub
rear panel port on the Master SG-6005xl unit, as illustrated in
Figure 3
1 Warning that you need to unlock to regain control via the front panel