Using the SG-6005xl Genlock Multistandard SPG/Audio Generator
KRAMER: SIMPLE CREATIVE TECHNOLOGY
8
The LEFT and RIGHT ANALOG RCA connectors to an analog stereo
audio acceptor (for example, the audio input on the Kramer VS-808xl
8x8 Video/Audio Matrix Switcher)
The AES-75Ω BNC connectors (for channels 1+2 and 3+4) to AES-75Ω
(AES-3id) digital stereo audio acceptors
1
The AES/ABU XLR connectors (for channels 1+2 and 3+4) to
AES/EBU digital audio acceptors
1
The LEFT and RIGHT BALANCED ANALOG XLR connectors to an
analog balanced stereo audio acceptor
1
3. If required
1
A Genlock source to the REFERENCE INPUT BNC connector
, connect:
2
The LOOP BNC connector to the INPUT BNC connector of the next
unit in the line, and release the TERM button for looping
3
4. If required, connect a PC and/or controller to the RS-232 port (see
Section 7
5. Connect the power connector to the mains electricity
).
1
.
7 Using the SG-6005xl Genlock Multistandard SPG/Audio
Generator
This section describes how to:
• Operate the SG-6005xl (see
Section 7.1
• Use front PANEL LOCK button (see
)
Section 7.2
7.1 Operating the SG-6005xl Genlock Multistandard SPG/Audio Generator
)
The SG-6005xl can save and load up to 16 setups via the menu.
To use the menu, press the:
• MENU button to start the menu
• ENTER button to accept changes
• and buttons to scroll through the menu and submenus
• and to increase or decrease numerical values or select from several
definitions of a setup
Upon exiting the menu, the SAVE SETTING AS item appears.
Table 2 defines the menu items.
Table 2: The SG-6005xl Menu
1 LOAD SETUP NUMBER … 1 to 16 (press ENTER to load)
2 SAVE SETTING AS SETTING NUMBER … 1 to 16 (press ENTER to save)
1 Not illustrated in Figure 2
2 Press the GENLOCK button to toggle between a genlocked generator and a free-running generator
3 Pushed in terminates the input. Release when the input extends to another unit