Connecting the Remote Control Machine
17
Table 6 defines the Machine # DIP-switch settings:
Table 6: Machine # DIP-switch Settings
Mach. # DIP 1 DIP 2 DIP 3 DIP 4 Mach. # DIP 1 DIP 2 DIP 3 DIP 4
1 ON OFF OFF OFF 9 ON OFF OFF ON
2 OFF ON OFF OFF 10 OFF ON OFF ON
3 ON ON OFF OFF 11 ON ON OFF ON
4 OFF OFF ON OFF 12 OFF OFF ON ON
5 ON OFF ON OFF 13 ON OFF ON ON
6 OFF ON ON OFF 14 OFF ON ON ON
7 ON ON ON OFF 15 ON ON ON ON
8 OFF OFF OFF ON
When connecting several controllers and a switcher, the machine numbers of
all the units within the system should be identical.
When controlling a system via:
RS-232, set the machine number on all units to 1 (see section 6.1)
RS-485, set the same machine # on all units excluding #1 (see section
6.4)
If, for example, the controlled switcher is set to machine # 3, then the
connected controllers should also be set to # 3