KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the Remote Control Machine
16
RS-485 PINOUT
G
B
A
_
+
Kr am er Swit cher
OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
Figure 8: Controlling via RS-485
6.5 Setting the DIP-switches
By default, all DIP-switches are set to OFF. Figure 9 illustrates the RC-160
DIP-switches:
OFF
ON
1 2 3 4 5 6 7 8
Figure 9: RC-160 DIP-switches
Table 5: DIP-switch Settings
DIPS Function Description
1, 2, 3, 4 Machine number See Table 6
5, 6, 7 Reserved Set to OFF
8 RS-485 TERM
ON for RS-485 Line Termination with 120;
OFF for no RS-485 Line Termination