KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol15F
12
Figure 13: Atmel Flip Window (Operation Completed)
10. Close the Atmel Flip window.
11. Disconnect the power on the PL-8.
12. If required, disconnect the RS-232 terminal block connector on the PL-8
unit from the Null-modem adapter.
13. Slide the underside PROGRAM switch back to normal.
14. Connect the power to the PL-8.
7 Kramer Protocol
1
By default, the PL-8 is set to protocol 3000 (see section
7.1) but is also
compatible with Kramer’s Protocol 2000 (see section 7.2).
You can switch protocols by setting DIP-switch 8 OFF for protocol 3000 and
ON for protocol 2000.
7.1 PL-8 Commands in Protocol 2000
This RS-232/RS-485 communication protocol uses four bytes of information
as defined below. For RS-232, a null-modem connection between the
machine and controller is used. The default data rate is 9600 baud, with no
parity, 8 data bits and 1 stop bit.