VP-774AMP - The VP-774AMP RS-232 Communication Protocol
Network settings commands
Network settings commands require admin authorization
Command
Syntax
Response
protocol
Ethernet port
ETHP
RESULT
Read protocol
Ethernet port
ETH-PORT? PROTOCOL
ETHP?
ETH-PORT PROTOCOL , PORT
PROTOCOL = TCP / UDP (transport layer protocol)
PORT =
Ethernet port to enter protocol 3000 commands.
1-65535 = User defined port
0 - reset port to factory default (50000 for UDP, 5000 for TCP)
Load new
peripheral
firmware P
Step 1: LDFW SIZE
Response 1: READY or LDFW SIZE ERR###
Step 2: If ready was received, send FIRMWARE_DATA
P
Response 2: LDFW SIZE RESULT
Load new video
core firmware
Step 1: LDFWS SIZE
Response 1: READY or LDFWS SIZE ERR###
Step 2: If ready was received, send FIRMWARE_DATA
P
Response 2: LDFWS SIZE RESULT
Load new
audio/graphic
memory file
Step 1: LDMFS SIZE
Response 1: READY or LDMFS SIZE ERR###
Step 2: If ready was received, send FIRMWARE_DATA
P
Response 2: LDMFS SIZE RESULT