Kramer Electronics RC-74DL Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
RC-74DL - Overview
7
#
Feature
Function
7
K-NET1 Connector
Connect the GND pin to the Ground connection; pin
B (-) and pin A (+) are for RS-485, and the +12V pin
is for powering the unit
The ground connection is sometimes connected to the
shield of the RS-485 cable (in most applications, it is
not connected)
8
K-NET2 Connector
Connect the GND pin to the Ground connection
(see Section 4.3; pin B (-) and pin A (+) are for
RS-485, and the +12V pin is for powering the unit
9
Ring Tongue Terminal Grounding
Screw
Connect to grounding wire (optional), (see
Section 4.3)
10
GP I/O Terminal Blocks (1 and 2)
Connect to various sensors, switches, LEDs, or
relays
11
Rel (Relay) Terminal Blocks
Connect to low-voltage relay-driven devices (from 1
to 4)
12
Switch
For internal factory use only
13
RS-485 Termination Switch
Slide down for RS-485 termination with 120; slide
up for no RS-485 Line Termination
The first and the last units on the RS-485 line should
be terminated (ON). Other units should be
unterminated (OFF)
14
RS-485 Terminal Block Connector
Connect to the RS-485 detachable terminal block
on a switcher or PC
15
RS-232 Terminal Blocks
Connect to the RS-232 devices (from 1 to 3)
16
IR Output Terminal Blocks
Connect to IR emitter cables (from 1 to 2)